Simultaneous separation and preconcentration of Ni(II) and Cu(II) ions by coprecipitation without any carrier element in some food and water samples
Abstract
A simple and highly sensitive separation and preconcentration procedure, which has minimal impact on the environment, has been developed. The procedure is based on the carrier element-free coprecipitation of Ni(II) and Cu(II) ions by using 2-{4-[2-(1H-Indol-3-yl)ethyl]-3-(4-chlorobenzyl)-5-oxo-4,5-dihydro-1H-1,2,4-triazol-1-yl}-N?-(pyrrol-2-ylmethyliden)acetohydrazide (ICOTPA), as an organic coprecipitant. The levels of analyte ions were determined by flame atomic absorption spectrometry. The detection limits for Ni(II) and Cu(II) ions were found to be 0.27 and 0.58 ?g L-1, respectively, and the relative standard deviations for the analyte ions were lower than 4.0%. Spike tests and certified reference material analyses were performed to validate the method. The method was successfully applied for the determination of Ni(II) and Cu(II) ions levels in sea and stream water as liquid samples and red lentil and rice as solid samples. © 2013 Institute of Food Science and Technology.
Source
International Journal of Food Science and TechnologyVolume
49Issue
6Collections
Related items
Showing items related by title, author, creator and subject.
-
Simultaneous separation and preconcentration of Cd(II), Co(II), and Ni(II) ions in environmental samples by carrier element-free coprecipitation method prior to their flame atomic absorption spectrometric determination
Duran C.; Ozdes D.; Akcay H.T.; Serencam H.; Tufekci M. (Taylor and Francis Inc., 2015)ABSTRACT: In the present study, Cd(II), Co(II), and Ni(II) ions were separated and preconcentrated via carrier element-free coprecipitation (CEFC) method by using an organic coprecipitating agent, 1,2-bis-(2-tosyl ethoxy) ... -
Application of carrier element free coprecipitation (CEFC) method for determination of Co(II), Cu(II) and Ni(II) ions in food and water samples
Serencam H.; Duran C.; Ozdes D.; Bektas H. (2013)A simple and highly sensitive separation and preconcentration procedure, which has minimal impact on the environment, has been developed. The procedure is based on the carrier element free coprecipitation (CEFC) of Co(II), ... -
Selective separation, preconcentration and determination of Pd(II) ions in environmental samples by coprecipitation with a 1,2,4-triazole derivative
Ozdes D.; Duran C.; Serencam H.; Sahin D.; Gundogdu A.; Soylak M. (Chemical Society of Ethiopia, 2015)A simple, sensitive, facile and low cost methodology, combined with flame atomic absorption spectrometry (FAAS), was employed to evaluate the selective separation and preconcentration of Pd(II) ions in environmental samples ...