    Application of carrier element free coprecipitation (CEFC) method for determination of Co(II), Cu(II) and Ni(II) ions in food and water samples
    (2013) Serencam H.; Duran C.; Ozdes D.; Bektas H.
    A simple and highly sensitive separation and preconcentration procedure, which has minimal impact on the environment, has been developed. The procedure is based on the carrier element free coprecipitation (CEFC) of Co(II), Cu(II), and Ni(II) ions by using 2-{4-[2-(1H-indol-3-yl)ethyl]-3-(4-methylbenzyl)-5-oxo- 4,5-dihydro-1H-1,2,4-triazol- 1-yl}-N'-(pyridin-2-yl methylidene)acetohydrazide (IMOTPA), as an organic coprecipitant. The levels of analyte ions were determined by flame atomic absorption spectrometry (FAAS). The detection limits for Co(II), Cu(II) and Ni(II) ions were found to be 0.40, 0.16 and 0.17 ?g L-1, respectively, and the relative standard deviations for the analyte ions were lower than 3.0%. Spike tests and certified reference material analyses were performed to validate the method. The method was successfully applied for the determination of Co(II), Cu(II) and Ni(II) ions levels in sea and stream water as liquid samples and red pepper, black pepper, and peppermint as solid samples.
  • Küçük Resim Yok
    Öğe
    Simultaneous separation and preconcentration of Ni(II) and Cu(II) ions by coprecipitation without any carrier element in some food and water samples
    (Blackwell Publishing Ltd, 2014) Duran C.; Tumay S.O.; Ozdes D.; Serencam H.; Bektas H.
    A simple and highly sensitive separation and preconcentration procedure, which has minimal impact on the environment, has been developed. The procedure is based on the carrier element-free coprecipitation of Ni(II) and Cu(II) ions by using 2-{4-[2-(1H-Indol-3-yl)ethyl]-3-(4-chlorobenzyl)-5-oxo-4,5-dihydro-1H-1,2,4-triazol-1-yl}-N?-(pyrrol-2-ylmethyliden)acetohydrazide (ICOTPA), as an organic coprecipitant. The levels of analyte ions were determined by flame atomic absorption spectrometry. The detection limits for Ni(II) and Cu(II) ions were found to be 0.27 and 0.58 ?g L-1, respectively, and the relative standard deviations for the analyte ions were lower than 4.0%. Spike tests and certified reference material analyses were performed to validate the method. The method was successfully applied for the determination of Ni(II) and Cu(II) ions levels in sea and stream water as liquid samples and red lentil and rice as solid samples. © 2013 Institute of Food Science and Technology.

| Bayburt Üniversitesi | Kütüphane | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Bayburt Üniversitesi Kütüphane ve Dokümantasyon Daire Başkanlığı, Bayburt, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim