Determination of the effect of volcanic pumice replacement on macro void development for blended cement mortars by computerized tomography
dc.authorid | 35367279600 | |
dc.authorid | 56473596300 | |
dc.authorid | 23476480900 | |
dc.contributor.author | Tekin I. | |
dc.contributor.author | Birgul R. | |
dc.contributor.author | Aruntas H.Y. | |
dc.date.accessioned | 20.04.201910:49:12 | |
dc.date.accessioned | 2019-04-20T21:44:36Z | |
dc.date.available | 20.04.201910:49:12 | |
dc.date.available | 2019-04-20T21:44:36Z | |
dc.date.issued | 2012 | |
dc.department | Bayburt Üniversitesi | en_US |
dc.description.abstract | In this study, the effect of volcanic pumice replacements with different ratios on the macro void development was observed using CT for a period of 100 days. The cured mortar specimens were imaged by X-ray CT on different days of the experiment. Utilizing Hounsfield Unit values as guides, void volumes and ratios were identified and measured by Matlab software. SEM images supported the X-ray CT results. It is shown that X-ray CT analysis is capable of assessing the development of macro voids in the mortar specimens. © 2012 Elsevier Ltd. All rights reserved. | en_US |
dc.identifier.doi | 10.1016/j.conbuildmat.2012.02.084 | |
dc.identifier.endpage | 22 | |
dc.identifier.issn | 0950-0618 | |
dc.identifier.scopus | 2-s2.0-84859487342 | en_US |
dc.identifier.scopusquality | Q1 | en_US |
dc.identifier.startpage | 15 | |
dc.identifier.uri | https://dx.doi.org/10.1016/j.conbuildmat.2012.02.084 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12403/895 | |
dc.identifier.volume | 35 | |
dc.identifier.wos | WOS:000309493700003 | en_US |
dc.identifier.wosquality | Q1 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.relation.ispartof | Construction and Building Materials | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Blended cement | |
dc.subject | Computerized tomography | |
dc.subject | Image analysis | |
dc.subject | Mortar | |
dc.subject | SEM | |
dc.subject | Blended cement | |
dc.subject | Hounsfield units | |
dc.subject | Matlab- software | |
dc.subject | Mortar specimens | |
dc.subject | SEM image | |
dc.subject | Void volume | |
dc.subject | Volcanic pumices | |
dc.subject | X-ray CT | |
dc.subject | Image analysis | |
dc.subject | Macros | |
dc.subject | Mortar | |
dc.subject | Scanning electron microscopy | |
dc.subject | Volcanoes | |
dc.subject | X rays | |
dc.subject | Computerized tomography | |
dc.subject | Blended cement | |
dc.subject | Computerized tomography | |
dc.subject | Image analysis | |
dc.subject | Mortar | |
dc.subject | SEM | |
dc.subject | Blended cement | |
dc.subject | Hounsfield units | |
dc.subject | Matlab- software | |
dc.subject | Mortar specimens | |
dc.subject | SEM image | |
dc.subject | Void volume | |
dc.subject | Volcanic pumices | |
dc.subject | X-ray CT | |
dc.subject | Image analysis | |
dc.subject | Macros | |
dc.subject | Mortar | |
dc.subject | Scanning electron microscopy | |
dc.subject | Volcanoes | |
dc.subject | X rays | |
dc.subject | Computerized tomography | |
dc.title | Determination of the effect of volcanic pumice replacement on macro void development for blended cement mortars by computerized tomography | en_US |
dc.type | Article | en_US |