An application of finite element method in material selection for dental implant crowns

dc.authoridSENSOY, Abdullah/0000-0002-9371-8307
dc.contributor.authorSensoy, Abdullah T.
dc.contributor.authorColak, Murat
dc.contributor.authorKaymaz, Irfan
dc.contributor.authorFindik, Fehim
dc.date.accessioned2024-10-04T18:48:11Z
dc.date.available2024-10-04T18:48:11Z
dc.date.issued2021
dc.departmentBayburt Üniversitesien_US
dc.description.abstractMaterials used for dental crowns show a wide range of variety, and a dentist's choice can depend on several factors such as patient desires, esthetics, tooth factors, etc. One of the most important issues for implant surgery is the primary stability and it should be provided to minimize the risks of screw loosening, failed osseointegration, or nonunion. The current study aims to present the Finite Element Analysis (FEA)-based material selection strategy for a dental crown in terms of reducing the aforementioned risks of dental implants. A virtual surgery mandible model obtained using MIMICS software was transferred to the ANSYS and material candidates determined using CES software were compared using FEA. The results indicated that ZrO2+Y2O3 (zirconia) has shown a 12.79% worse performance compared to Au83-88/Pt4-12/Pd4.5-6 alloy in terms of abutment loosening. On the other hand, zirconia is the most promising material for dental crowns in terms of the stability of the bone-implant complex. Therefore, it may show the best overall performance for clinical use. Moreover, as suggested in this study, a better outcome and more accurate predictions can be achieved using a patient-specific FEA approach for the material selection process.en_US
dc.identifier.doi10.1515/bmt-2020-0232
dc.identifier.endpage436en_US
dc.identifier.issn0013-5585
dc.identifier.issn1862-278X
dc.identifier.issue4en_US
dc.identifier.pmid33837682en_US
dc.identifier.scopus2-s2.0-85104430505en_US
dc.identifier.scopusqualityQ3en_US
dc.identifier.startpage429en_US
dc.identifier.urihttps://doi.org/10.1515/bmt-2020-0232
dc.identifier.urihttp://hdl.handle.net/20.500.12403/2956
dc.identifier.volume66en_US
dc.identifier.wosWOS:000681637400011en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherWalter De Gruyter Gmbhen_US
dc.relation.ispartofBiomedical Engineering-Biomedizinische Techniken_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectbiomedical modelingen_US
dc.subjectdental crownen_US
dc.subjectfinite element analysisen_US
dc.subjectimplanten_US
dc.subjectmaterial selectionen_US
dc.titleAn application of finite element method in material selection for dental implant crownsen_US
dc.typeArticleen_US

Dosyalar